Aquadopp Profiler Z-Cell 2 - 1 MHz
Up to 25 m current profiling range and no blanking; can measure near-surface or near-bottom currents
Need to collect accurate 3D currents very near the seabed or sea surface, in addition to a full water-column profile?
Description
The Z-Cell (Zero Cell) Aquadopp Profiler allows current measurement to start right at the instrument’s level through an innovative approach: it has side-looking beams fully integrated into the instrument’s head, effectively removing the blanking distance normally applicable to ADCPs.
Do you have questions about this product?
- Questions about price, availability, and/or retailers
- Questions about technical specifications and usage
- Questions about suitability for your project or application
Specifications
-
General
-
Housing Material
POM, Naval Brass, Titanium Gr.5, Epoxy
Length [m]
0.602
Max. operating depth [m]
500
Weight in air [kg]
2.280
Weight in water [kg]
-0.4
Width [m]
0.075
Total Weight [kg]
2.280
Year of last update
2024
-
Other specifications
-
External battery container
Y
Max. cable length [m]
50
Data acquisition software and processing software
Nortek software
-
Auxiliary Sensors
-
Pressure
Y
Wave direction
Y
Waves
Y
-
Deployment method
-
Bottom mount
Y
Moving vessel
N
-
Doppler Current Profiler
-
Center working frequency [kHz]
1000
Max. cell size [m]
4
Max. Number of cells per beam
200
Max. ping rate [Hz]
1
Max. velocity [m/s]
11.5
Max. typical profiling range [m]
25
Min. blanking distance [m]
0
Min. cell size [m]
0.25
Number of beams
5
Minimum accuracy
±1% of measured value ±0.5 cm/s
Maximum sampling rate for Water velocity measurements
1 Hz
Pressure
Piezoresistive
Compass and tilt
Solid state magnetometer / solid state accelerometer
Data recording
16 GB
DC Input
9-24 V DC
Storage temperature
-20 to +60 °C
Shock and vibration
Shock: IEC 60068-2-27, Vibration: IEC 60068-2-64
EMC approval
EN IEC 61000-6-2:2019, EN IEC 61000-6-4:2019
Depth rating
500 m
Velocity resolution of Depth measurements
1 cm/s
IO
RS-422 (Inquire for RS-232)
Connectors
MCBH-8-FS Brass
Material
POM, Naval Brass, Titanium Gr.5, Epoxy
-
Standard Sensors
-
Compass type
Solid State
Temperature: max. [°C]
40
Temperature: min [°C]
-4
-
Application
-
Typical applications
Mounted on bottom frames, with ability to also measure near-bed currents; Mounted on surface buoys, with the ability to measure also surface currents; Mean flow measurements with high focus on ease of use and simplicity; Measurements of combinations of waves and currents