Measures conductivity, temperature, depth, dissolved oxygen, pH, turbidity, and chlorophyll. It is ideally suited for extended deployments in remote, biologically rich environments, for depths to 350m. Specifically designed for long-term deployments in remote, biologically rich environments, it comes equipped with multiple anti-fouling systems.
Description
Measures conductivity, temperature, depth, dissolved oxygen, pH, turbidity, and chlorophyll. It is ideally suited for extended deployments in remote, biologically rich environments, for depths to 350 m.
Specifications
-
General
-
Year of initial development
2016
Weight in air [kg]
4
Diameter [mm]
62
Length [mm]
711
Max. cable length [m]
350
Housing Material
350 m plastic housing
-
Observations
-
Min. time increment [s]
10
-
Operation Characteristics
-
Data display on dedicated hardware
N
-
Pressure, temperature and conductivity sensor
-
Max. conductivity [S/m]
7
Resolution of conductivity [10^-3 S/m]
0.01
Min. temperature [Ā°C]
-5
Max. temperature [Ā°C]
45
Resolution of temperature [Ā°C]
0.0001
Resolution of pressure [% FS]
0.002
Pressure sensor
Y
Type of pressure sensor
strain-gauge
Temperature sensor
Y
Type of temperature sensor
thermistor
Conductivity sensor
Y
Type of conductivity sensor
internal-field electrode cell
Accuracy of pressure sensor
Ā± 0.1% of full scale range
Accuracy of temperature measurement
Ā± 0.002 Ā°C (-5 to +35 Ā°C); Ā± 0.01 (+35 to +45 Ā°C)
Accuracy of conductivity measurement
0.003 mS/cm (0.0003 S/m)
-
Software specifications
-
Recording with third party software
N
Software name
Sea-Bird Scientific UCI
Graphical presentation
Y
Raw data editing
N
-
Environmental
-
Max. depth [m]
350
Max. pressure [bar]
350
Operating temperature: min. [Ā°C]
-5
Operating temperature: max. [Ā°C]
45
-
Data and connectivity
-
Max. number of samples for self-recording [10^3]
215
External recorder required
N
Dedicated surface data logger
N
Dedicated sub-surface data logger
N
Telemetry link to remote location
Y
Direct data reading
Y
Internal memory
Y
Internal Memory [MB]
16
Type of internal memory
FLASH
-
Power
-
Battery type
12 AA lithium cells
Min. operating power [V]
9
Max. operating power [V]
24
Battery
Y
-
Additonal sensors
-
Standard sensor
Conductivity, temperature, depth, dissolved oxygen, pH, turbidity, and chlorophyll.
No. of additional sensors
0
-
More information
-
Distinguishable features
Specifically designed for long-term deployments in remote, biologically rich environments, it comes equipped with multiple anti-fouling systems.