Join 40,000+ geospatial professionals and get technology news delivered straight to your inbox every week. Subscribe today.

AWAC 2 - 600 kHz

Real-time current profiles and directional waves for intermediate water

The AWAC 600 kHz ADCP has become the standard reference technology in submerged wave-measurement applications. Thousands of these ADCPs have been deployed to capture the full wave spectrum in combination with current profiles. With a 60 m maximum range for wave measurements and 2 Hz sampling of the surface elevation, the AWAC 600 kHz is the optimal tool for medium water-depth current and wave measurements. The AWAC 2 design offers future-proof electronics, improved performance and easier deployment and maintenance.

Description

Highlights

  • Real-time current profiles and waves to 50 m range

  • Acoustic surface tracking (AST) with vertical beam

  • Can be used both with fixed frames and subsurface buoys

Usage

  • Online measurements of currents and waves

  • Design data for planning of new coastal structures

  • Site studies for offshore wind platforms

  • Monitoring of transient waves for channel wall protection

  • Studies of tidal currents

Do you have questions about this product?

  • Questions about price, availability, and/or retailers
  • Questions about technical specifications and usage
  • Questions about suitability for your project or application

Specifications

Physical Properties

Length [cm]

20.3

Operating temperature: min. [°C]

-4

Operating temperature: max. [°C]

40

Housing material

POM with titanium fasteners

General

Area of Application

Real-time current profiles and directional waves for intermediate water

Field of Use

Online measurements of currents and waves, Design data for planning of new coastal structures, Site studies for offshore wind platforms

Output parameters

Real-time current profiles and waves to 50 m range

Direction wave or non-directional

Directional

Year of initial development

2001

Year of latest version

2024

Operating properties

Sampling rate

1Hz or 2Hz

Max. depth rating [m]

300

Power supply and communication

Power supply (internal/external with specs)

DC input: 12-48 V. DC Maximum peak current: 1.5 A. Avg. power consumption: 15 mW. Sleep current: < 100 μA.

Output interface {eg. rs232}

Ethernet, RS-232 or RS-422

Hardware/software requirements

Dedicated software

Y

Compass sensor

Range

0 - 360 °

Resolution

2° for tilt <30° / 0.01°

Current sensor

Range

±10 m/s horizontal, ±20 m/s upon request

Accuracy

±1% of measured value ±0.5 cm/s

Temperature sensor

Range

-4 to +40 °C

Accuracy

0.1 °C

Resolution

0.01°C

Pressure sensor

Range

0-100m (inquire for options)

Accuracy

0.5% of full scale (optional 0.1% of full scale)

Resolution

0.1% FS / Better than 0.002% of full scale

Ask a question

Nortek team is happy to assist.

Nortek

We're available on all weekdays and usually reply within 1-2 working days.

Please provide detailed information. Your input helps Nortek assist you effectively.

Let us know a little about you and your contact information.

Do you represent a company or organization?

Before we proceed, would you be interested in subscribing to our newsletter?

By completing this form, you acknowledge and agree to abide by our Terms and Conditions, Privacy Policy and Cookie Policy.

Thank you for your message! Our team tipically to respond to inquiries within 1-2 business days.