Join 40,000+ geospatial professionals and get technology news delivered straight to your inbox every week. Subscribe today.

AML-3 LGR SVP 6000m

AML-3 LGR SVP 6000m

The AML-3 SVP 6000m is an all inclusive package built around the AML-3 Logger with Sound Velocity and Pressure (6000 dBar) X2change™ sensors.

Description

The AML-3 series is a highly configurable family of multiparameter sondes designed for a wide range of data collection applications. The ‘3’ designation refers to the number of sensors that may be simultaneously installed on the instrument’s endcap. This kit comes with sound velocity and 6000 dbar pressure X2change™ sensors.

The LGR versions (ie. AML-3 LGR) are self-powered via a rechargeable internal battery and have a mechanical on/off switch on the bulkhead. The AML-3 LGR is most commonly used for vertical profiling of the water column with internal logging of sensor measurements and seamless data transfer via USB on recovery.

X2change™ is the industry’s leading family of field-swappable sensor heads. Each sensor head contains its own embedded calibration and can be moved from instrument to instrument without impacting accuracy. Changing sensors is easy: simply unscrew one sensor head and replace it with another.

Key Benefits:

Zero Down Time – With X2•Series sensors, recalibrated sensors are sent to the instrument instead of sending the instrument to the recalibration centre.

Reduce Logistical Costs – With X2•Series small sensor heads are shipped instead of heavy instruments.

Increased Flexibility – Field-swappable sensor heads enable any organization – big or small – to become a virtual recalibration centre by stocking spare calibrated sensor heads.

One Instrument, Multiple Applications – the ability to change sensor type on any instrument to suit specific application requirements. This means instrument duplicates (identical instruments dedicated to different pressure ranges, separate instrument for Turbidity, pH, Chlorophyll, etc) become a thing of the past.

Improved absolute pressure accuracy – You may choose the best full scale pressure range to suit your deployment depth.

*Please note that specs may change depending on X2change™ sensor configuration.

Do you have questions about this product?

  • Questions about price, availability, and/or retailers
  • Questions about technical specifications and usage
  • Questions about suitability for your project or application

Specifications

General

Diameter [mm]

76

Height [mm]

343

Weight in air [kg]

2.5

Weight in water [kg]

1.9

Material

Titanium housing with stainless steel protective cage

Temperature, Depth and other Sensors

Temperature sensor

Optional

Temperature resolution [°C]

0.001

Temperature measurement accuracy [%]

0.005 °C

Pressure sensor

Y

Pressure resolution [%]

0.02

Pressure measurement accuracy [%]

0.05

GPS sensor

N

Other sensors

Instrument compatible with all other X2change Sensors including Conductivity & Temperature, Turbidity, Dissolved Oxygen, and more. Please contact AML Oceanographic for customized configurations.

Power

Min. operating power [V]

8

Max. operating power [V]

30

Battery

Y

Battery type

Lithium ion

Max. operation time on one battery [hr]

14

Max power consumption [W]

10

Environmental

Max. operating depth [m]

6000

Max. pressure [bar]

6000

Operating temperature: min. [°C]

-20

Operating temperature: max. [°C]

45

More information

Distinguishable features

Exchangeable technology ensures total flexibility of sensor configuration, regardless of application.

Data/Software specifications

Connectors

USB

Output data/formats

Columns/custom

Internal memory

Y

Internal Memory [MB]

32000

Type of internal memory

SD Card

Software solution

Y

Sound Velocity

Sample rate [Hz]

User configurable up to 20

Range min. value [m/s]

1375

Range max. value [m/s]

1625

Sound Velocity Performance

Resolution [m/s]

0.001

Accuracy [m/s]

0.025

Precision [m/s]

0.006

Operation Characteristics

Moving vessel profiling compatibility

N

Accessories

USB-C interface cable, plug-in outlet adapters, USB WiFi adapter, Sailfish software, watertight transit case

Calibration procedure

Consult factory or approved third party

Documents

Brochure
aml-3-211005-2.pdf
359.52 KB
aml-3-211005-2.pdf
Other documents
  • X2change Sensor Datasheet (7)
    302.06 KB

Ask a question

AML Oceanographic team is happy to assist.

AML Oceanographic

We're available on all weekdays and usually reply within 1-2 working days.

Please provide detailed information. Your input helps AML Oceanographic assist you effectively.

Let us know a little about you and your contact information.

Do you represent a company or organization?

Before we proceed, would you be interested in subscribing to our newsletter?

By completing this form, you acknowledge and agree to abide by our Terms and Conditions, Privacy Policy and Cookie Policy.

Thank you for your message! Our team tipically to respond to inquiries within 1-2 business days.