Specifications

  • Year of initial development
    1978
  • Max. power consumption [W]
    50.00
  • Min. external DC power [V]
    11
  • Max. external DC power [V]
    14
  • Min. external AC power [V]
    87
  • Max. external AC power [V]
    264
  • Weight in air [kg]
    16.00
  • Width [m]
    0.430
  • Length [m]
    0.500
  • Height [m]
    0.190
  • Software platform
    Tablet PC, Windows Mobile, Windows Vista, Windows XP
  • Max. depth of operation [m]
    1000.0
  • Min. frequency [kHz]
    38.0
  • Max. frequency [kHz]
    1000
  • Number of simultaneous frequencies
    4
  • Standard power output [W]
    1000
  • Min. beam angle [deg]
    6.00
  • Max. beam angle [deg]
    10.00
  • Depth resolution [m]
    0.02
  • Max. sounding rate [Hz]
    30
  • Min. pulse length [ms]
    0.100
  • Max. pulse length [ms]
    1.000
  • Dynamic range [dB]
    130
  • Remote operation capability
    Y
  • Marking of events and other annotations
    Y
  • Real-time sound velocity and temperature profile inclusion
    N
  • Real-time coupling to survey/post-processing software
    N
  • Data displayed in real time
    Depth; echo strength; position
  • Data output options
    Raw acoustic data samples; post-processing for all variables other than depth
  • Data output formats
    BioSonics DT-4; ICES HAC format
  • Data output for sea floor classification
    N
  • Data display details
    Visual echogram; digital depth and position. Echo envelope on oscilloscope
  • Connectors
    LAN
  • Internal data logging details
    Solid-state
  • Main use of the system
    Habitat assessment (bathymetry; substrate classification; vegetation assessment and biological biomass)