Kongsberg Maritime CONTROS HydroC CH4 underwater methane sensor

The CONTROS HydroC® CH4 sensor is a unique subsea / underwater methane sensor for in-situ and online measurements of CH4 partial pressure (p CH4). The versatile CONTROS HydroC® CH4 provides the perfect solution for the monitoring of background CH4 co

  • Kongsberg Maritime CONTROS HydroC CH4 underwater methane sensor
Kongsberg Maritime
Strandpromenaden 50
3191 Horten
Norway
Contact supplier
Documents
Download brochure

Description

The CONTROS HydroC® CH4 sensor is a unique subsea / underwater methane sensor for in-situ and online measurements of CH4 partial pressure (p CH4). The versatile CONTROS HydroC® CH4 provides the perfect solution for the monitoring of background CH4 concentrations and for long-term deployments.

Specifications

  • Field of Use
    The versatile CONTROS HydroC® CH4 provides the perfect solution for the monitoring of background CH4 concentrations and for long-term deployments.
  • Sensor type
    Methane
  • RAM memory [GB]
    2
  • HD [GB]
    0.2
  • Operating System
    Win 7 32 Bit
  • Dedicated software
    Y
  • Software
    CONTROS DETECT® incl. real-time data visualization, setting of sensor parameters, download data from internal data logger and sleep mode function
  • Output interface {eg. rs232}
    RS-232C and RS-485
  • Output format {eg. ascii}
    ASCII
  • Power supply min. [V]
    12
  • Power supply max. [V]
    30
  • Weight in air [kg]
    12.5
  • Weight in water [kg]
    5.5
  • Width [m]
    0.136
  • Length [m]
    0.528
  • Min. operating temperature [°C]
    -2
  • Max. operating temperature [°C]
    35
  • Mounting possibilities
    ROV and AUV installation packages. Profiling and mooring frames.
  • Max. operating depth [m]
    3000
  • Methane sensor type
    Dissolved CH4 molecules diffuse through a custom made thin film membrane into the internal gas circuit leading to a detector chamber, where the CH4 concentration is determined by means of Tunable Diode Laser Absorption Spectroscopy (TDLAS). Concentration dependent laser light intensities are converted into the output signal from calibration coefficients stored in firmware and data from additional sensors within the gas circuit.
  • Range [μatm]
    0- 40,000
  • Accuracy [μatm]
    2
  • Resolution [μatm]
    0.001
  • Initial accuracy {±% of reading)
    3
  • Distinguishable features
    Analogue output: 0 V - 5 V. Internal data logger. External battery packs. ROV and AUV installation packages. Profiling and mooring frames. External pump (SBE-5T or SBE-5M). Easy deployment together with a CONTROS HydroFlash® O2.