Your Product Platform for Surveying, Positioning and Machine Guidance Join Geo-matching now!

Nortek DVL 1000 - 4000 m

The Nortek's DVL is available as two models, the 1 MHz and 500 kHz. These two DVLs differ primarily in the operational depth and the expected bottom track range. Below you will find an overview of the features and benefits of the DVL. 

  • Nortek DVL 1000 - 4000 m
Nortek
Vangkroken 2
1351 Rud
Norway
Contact supplier
Videos



Documents
Download brochure

Description

The Nortek's DVL is available as two models, the 1 MHz and 500 kHz. These two DVLs differ primarily in the operational depth and the expected bottom track range. Below you will find an overview of the features and benefits of the DVL.     
The data specification sheets for the 1MHz model and the 500 kHz model provide detailed figures for performance.

Specifications

  • Width/Diameter [m]:
    0.135
  • Height [m]
    0.148
  • Weight in air [kg]
    2
  • Weight in water [kg]
    0.9
  • Housing material
    Titanium
  • Max. operating depth [m]
    4000
  • Year of introduction
    2015
  • System components
  • Min. external power DC [Voltage]
    12
  • Max. external power DC [Voltage]
    48
  • Max power consumption [W]
    8
  • Average power consumption [W]
    1.3
  • Number of concurrent power input ports
    2
  • Number of transducers
    4
  • Number of beams
    4
  • Transducer type
    Janus array convex transducer
  • Max transmit power
    217 dB ref 1uPa at 1m
  • Frequency operating range min.[kHz]
    875
  • Frequency operating range max.[kHz]
    1125
  • Vertical beam opening angle [°]
    25
  • Beam width [°]
    2.9
  • Individually replaceable transducers
    Y
  • Distinguishable features
    - small size- low power- long range- high precision- custom intergration
  • Velocity range [m/s]
    16
  • Velocity resolution [mm/s]
    0.01
  • Min. altitude [m]
    0.2
  • Max. altitude [m]
    50
  • Long term accuracy
    ±0.2% / ±0.1cm/s
  • Single Ping precision
    0.5 cm/s at 3 m/s
  • Interval
    User specified nth ping
  • Max. layer/cell size [m]
    2
  • Minimum range [m]
    0.3
  • Maximum Range [m]
    30
  • Long term accuracy
    1% of measured value or +/- 0.5m/s
  • Velocity resolution [m/s]
    0.001
  • Min. layer/cell size [m]
    0.2
  • Communication [RS232, USB, Ethernet]
    RS232 or RS485, 10/100 Mbits Auto MDI-XTCP/IP, UDP, HTTP protocolsFixed IP/DHCP client/AutoIP, UPnP
  • Connector type
    Subcon 8p MCBH female (serial), Subcon 8p MCBH (Et
  • Data baud rates
    300–1250000 baud (serial)
  • Number of possible concurrent outputs
    3
  • Internal memory [GB]
    64
  • Type of internal memory
    SD card
  • Requires separate software
    N
  • Time stamp in data
    1 millisecond precision, IEEE1588/PTP for absolute
  • Trigger
    1 millisecond precision, IEEE1588/PTP for absolute time stampingInternal 1, 2, 3, 4 or 8 HzTrigger option through command(Ethernet or serial)External TTL or 485 lines:- 1 input trigger (configurable Rising/Falling/Edge)
  • Concurrent output specifications
    3 dedicated ethernet port, UDP

You have selected 2 products to compare you can add 4 more products